How to upgrade the CC121

Instructions for upgrading a CC121 Arcnet Controller Module.

Version 1.2 to version 1.2 Level B

  • Replace 121-017-0 with 121-017-1
  • Add Level B sticker on P2

Version 1.1 to version 1.1 Level C

  • Replace 121-022-0 with 121-022-1, however first remove pins 1, 6 and 11, still keeping enough metal to solder wires to the pins
  • Add the following wires
    FromTo
    U22 pin 1U22 pin 19
    U22 pin 6U18 pin 9
    U22 pin 11U22 pin 10
    U22 pin 13U23 pin 15
    U22 pin 14U8 pin 13
    U18 pin 11P1A pin 21
  • Replace 121-017-0 with 121-017-1
  • Add Level C sticker on P2

Version 1.1 Level B to version 1.1 Level C

  • Replace 121-017-0 with 121-017-1
  • Add Level C sticker on P2